Dual technology motion detector IMA13

VAT-inclusive price
52.72EUR

432 Raccolta Punti

Dual technology detector equipped with Fresnel lens flat (cylindrical) interchangeably.

Inclination of the rays sensitive installations at different heights from 2.1 meters, you can adjust the position of the pyroelectric sensor, translating the printed circuit up or down.

Interchangeable lenses: the Fresnel volume factory, can be replaced with curtain lens or long-range options.

 

IMA13 COD. 80IM3100211

FEATURES

Capacity:
- Nominal 15 m (wide angle lens)
- 15 m nominal (curtain lens)
- 15 m nominal (long range lens)
 
IR coverage:
- 108 ° (wide angle lens)
 
MW coverage:
- 90 ° horizontal
- 36 ° vertical
 
Sensitive areas:
- 31 on 4 floors (wide angle lens)
- 1 out of 1 floor (curtain lens)
- 7 on 4 floors (long range lens)
 
Protected PIR: The PIR sensitive element is completely protected from disturbances due to insects and / or air drafts which might generate false alarms.
Protection halogen light: The lens coloring prevents false alarms that may be generated if the sensitive element be hit by white light rays.
AUTOEQUALIZER function: the MW section of the detector is equipped with Auto AUTOEQUALIZER for a dynamic adaptation of the alarm thresholds.
Operating logic: There are two modes of operation: AND1: the alarm
is generated if they are stressed both IR and MW sections; AND2: the alarm is triggered if they are stressed both IR and MW sections, or if the stress of the MW remains for a few seconds.
Control of stand-by time: using this input the detector is informed on the state (on or off). E 'can then program the detector so that this information can not block the alarm relay and the LED indicator.
Inhibition alarm relay: Possibility of programming the alarm output so that it is inhibited when the detector is in "stand-by".
Automatic temperature compensation: The detector is equipped with the automatic compensation bidirectional, ie when the ambient temperature increases and approaches the temperature of the human body involves a lowering of the intervention threshold; when the ambient temperature exceeds that of the human body the threshold returns
to increase.
Inhibition microwave emission: the detector placed in stand-by mode (system off) inhibits the emission generated by the microwave section.
Memory faults: The detector is able to detect fault situations, displaying
type by the flashing of the LED
  • Operating Voltage min-max: 9-15 Vdc
  • Rated supply voltage: 12 Vdc
  • Current consumption at 12VDC: 14 mA nom. , 35 mA max
  • Pulse Count: X1/X2
  • Alarm Relay: Solid State Relay NC 100 mA @ 24 Vdc / Rmax = 35 ohms
  • Tamper: 50 mA @ 24 Vdc
  • Operating temperature: -10 ° C / +55 ° C (manufacturer's declared value) +5 ° C to +40 ° C (certified according to IEC)
  • Performance level: Level I / II level with joint SPA10 and Tamper Kit
  • Dimensions (H x W x D): 124 x 70 x 54 mm
  • Weight: 124 g

Categories

Manufacturers