Seismic Detector for the alarm against burglary attempts made at the expense of building structures in reinforced concrete, safes, cabinets armor, Automated Teller Machines, etc.

As MS04 but with dustcover device for protection of safes with a possibility to discriminate between three positions: lock indoor lock discovery and intermediate.

Microprocessor technology with fully digital sensor management.

 

MS04 COD. 80MS0800211

FEATURES

  • Total immunity from external noise electromagnetic in nature thanks to the double galvanic isolation between the junction area and the unit of measurement and signal analysis
  • Cyclic self-test on the two detection channels, with constant monitoring of the integrity of the transducer
  • and amplification section
  • Equipped with heat detector threshold to detect attack attempts at the microphone with devices that abruptly alter the normal operating temperature
  • Channels and methods of detection:
  • Channel drilling: 16 levels of sensitivity, 4 - integration values ​​(delay)
  • Channel explosion: 4 sensitivity levels
  • Display and storage of different types of alarm
  • Test point for calibration and verification instrumental sensitivity
  • Command "REMOTE" for the mitigation of sensitivity levels (ATM applications)
  • Double cable routing: towards the center, with a cable gland, towards a possible auxiliary sensor, external microphone
  • Space to insert a "disruptive internal" (optional), adapted to the function
  • of operational test
  • Ability to manage "disruptive external" (optional), for operational testing
  • on large surfaces
  • Rated supply voltage: 12 Vdc
  • Voltage min. and max range: 9 to 15 Vdc
  • Power consumption: 25 mA typ 30 mA max at 12 Vdc
  • Certified working temperature: +5 ° C to +40 °
  • Operating temperature stated by the manufacturer: -10 ° C to +70 ° C
  • Activation temperature tampering attacks temperature: -5 ° C to +60 ° C
  • Cyclic self-test automatically every 5 minutes
  • * Guaranteed performance level:
  • III ° (with MS04IT + MS04ET)
  • II (with disturbing inside MS04IT)
  • I ° (standard microphone)
  • Degree of protection IP30 certified (IEC 70-1)
  • Degree of protection stated by the manufacturer: IP54
  • Alarm Time opto output: approx 4s
  • Revelation thermal gradient 4 ° C / min. about
  • Banda detected: from 10 to 100 Khz approximately
  • Covered area: 48 sqm
  • Alarm Output: solid state relay
  • Tamper output for opening, removal, thermal attacks
  • Dimensions (W x H x D): 136 x 48 x 89 mm
  • Weight 550 g